CryoSPARC v4.5.3+240807
This is a patch release. Learn how to apply patches to your instance →
The volume viewer now has improved reliability, with reduced likelihood of issues when multiple large volumes are loaded.
Streaming refinement in CryoSPARC Live now re-scales a provided input volume and mask to match the extent and pixel size of the extracted particles.
Reference Based Motion Correction no longer fails with an error indicating that there are micrographs with fewer than 2 particles, when particle re-centering is turned on.
Import Result Group job no longer fails when importing a result containing a Topaz model.
Fixed a bug that caused the 3D Flex Generator job to run out of GPU memory for large datasets.
Ab-initio Reconstruction no longer fails when upstream particles have alignments3D metadata attached, and the number of particles parameter is set.
Fixed a bug that would cause the 3D Classification job to fail when class re-ordering was on, and the number of classes exceeded 12.
Orientation Diagnostics no longer fails when using imported half-maps.
Removed unnecessary SSD requirement in the Regroup 3D job.
Removed unused parameter “Recenter templates” from the Blob Picker job.